No. |
Name of product/ good as stated in the Circular No. 65(i) |
HS code as stated in the Circular No. 65 |
Specific product as stated in the Circular No. 29(ii) |
HS code as stated in the Circular No. 29 |
Notes |
|
|
|
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
|
|
|
A |
Products subject to physical inspection before customs clearance |
|
|
|
||||
I |
Chemicals and industrial explosives |
|
|
|
||||
1 |
Explosive precursors (mixtures with content of explosive precursor(s) more than 45%) as per the Decree No. 39/2009/ND-CP(iii). |
|
|
|
||||
1.1 |
Ammonium nitrate, whether or not in aqueous solution |
3102.30.00 |
Ammonium nitrate (NH4NO3) in crystalline form for production of emulsion explosive |
3102.30.00 |
|
|
|
|
Ammonium nitrate (NH4NO3) in porous prills for production of ANFO explosive |
|
|
|
|
||||
B |
Products and good subject to post-clearance inspection |
|
|
|
|
|||
2 |
Industrial explosives as per the Decree No. 39/2009/ND-CP |
|
|
|
|
|||
2.1 |
Prepared explosives, other than propellent powders |
3602.00.00 |
Emulsion explosives for blasting in underground mines without detonation gas and dust |
3602.00.00 |
|
|
|
|
Ammonite Explosive AD1 |
|
|
|
|
||||
Other types of explosive (As per Section I - Appendix 1 enclosed to the Circular No. 45/2013/TT-BCT) |
|
|
|
|
||||
2.2 |
Semi-fuses; elemented caps |
3603.00.10 |
Electrical detonators for industrial use |
3603.00.10 |
|
|
|
|
Plain detonator No. 8 for industrial use |
|
|
|
|
||||
2.3 |
Safety fuses |
3603.00.20 |
Industrial safety fuses |
3603.00.20 |
|
|
|
|
2.4 |
Other |
3603.00.90 |
Water-resistant detonating cord for industrial use |
3603.00.90 |
|
|
|
|
Primer for industrial explosives |
|
|
|
|
||||
II |
Industrial machinery and equipment |
|
|
|
|
|||
1 |
High-pressure pipe capable of withstanding a pressure of not less than 42,000 psi |
7304.39.20 |
First-level or second-level pipeline for steam and hot water with minimum external diameter of 51 mm; third-level and fourth-level pipelines with minimum external diameter of 76 mm for industrial use |
7304.39.20 |
|
|
|
|
2 |
Equipment for scaffolding, shuttering, propping or pit-propping |
7308.40.10 |
Single hydraulic prop, mobile bracket and self-propelled platform composed of single hydraulic props for mine supporting |
7308.40.10 |
|
|
|
|
7308.40.90 |
7308.40.90 |
|
|
|
||||
3 |
Containers for any material |
7309.00.11 |
Pressure vessels of a structure not used on vehicles, with intended working pressure above 0.7 bar (not including hydrostatic pressure) for industrial use |
7309.00.11 |
|
|
|
|
7309.00.19 |
7309.00.19 |
|
|
|
||||
7309.00.91 |
7309.00.91 |
|
|
|
||||
7309.00.99 |
7309.00.99 |
|
|
|
||||
4 |
Containers for compressed or liquefied gas, of iron or steel, in the form of seamless steel cylinders |
|
|
|
|
|||
4.1 |
Other, of a capacity of not exceeding 7.3 l |
7311.00.91 |
LPG containers |
7311.00.93 |
|
|
|
|
4.2 |
Other, of a capacity of more than 7.3 l but less than 30 l |
7311.00.92 |
|
|
|
|||
4.3 |
Other, of a capacity of 30 l or more, but less than 110 l |
7311.00.94 |
|
7311.00.94 |
|
|
|
|
4.3 |
Other |
7311.00.99 |
LPG tanks of a structure not used on vehicles |
7311.00.99 |
Changes in applicable Regulations/ Standards: - TCVN 8615-1:2010 and TCVN 8615-2:2010 are abrogated. - TCVN 6486:2010 is added |
|
|
|
5 |
Super-heated water boilers generating steam or other vapour |
|
|
|
||||
5.1 |
Watertube boilers with a steam production exceeding 45 t per hour |
8402.11.10 |
Boilers of a structure not used on vehicles, with intended working pressure of vapour above 0.7 bar for industrial use |
8402.11.10 |
|
|
|
|
8402.11.20 |
8402.11.20 |
|
|
|
||||
5.2 |
Watertube boilers with a steam production not exceeding 45 t per hour |
8402.12.11 |
8402.12.11 |
|
|
|
|
|
8402.12.19 |
8402.12.19 |
|
|
|
||||
8402.12.21 |
8402.12.21 |
|
|
|
||||
8402.12.29 |
8402.12.29 |
|
|
|
||||
5.3 |
Other vapour generating boilers, including hybrid boilers |
8402.19.11 |
8402.19.11 |
|
|
|
|
|
8402.19.19 |
8402.19.19 |
|
|
|
||||
8402.19.21 |
8402.19.21 |
|
|
|
||||
8402.19.29 |
8402.19.29 |
|
|
|
||||
5.4 |
Super-heated water boilers |
8402.20.10 |
Boilers used in power plants |
8402.20.10 |
Applicable Regulations/ Standards: TCVN 7704:2007 and TCVN 6008:2010 are supplemented |
|
|
|
8402.20.20 |
8402.20.20 |
|
|
|
||||
6 |
Central heating boilers other than those of heading 84.02 |
8403.10.00 |
Water heaters with a boiling temperature exceeding 115oC for industrial use |
8403.10.00 |
Applicable Regulations/ Standards: TCVN 7704:2007 is abrogated |
|
|
|
7 |
Winches; capstans powered by electric motor |
8425.31.00 |
Hoists and windlasses with minimum working load of 10,000 N and lifting angles ranging from 25o to 90o for industrial use |
8425.31.00 |
Applicable Regulations/ Standards: QCVN 02:2016/BCT is supplemented |
|
|
|
8 |
Other machines and mechanical appliances |
8479.89.39 |
LPG filling station for containers, tank trucks and automobiles |
8479.89.30 |
|
|
|
|
8479.89.40 |
|
|
|
|||||
8479.89.39 |
LPG supply station |
|
|
|
||||
8479.89.40 |
|
|
|
|||||
9 |
Electric motors |
8501.10.29 |
Explosion-proof electric motors |
8501.10.29 |
|
|
|
|
8501.10.49 |
8501.10.49 |
|
|
|
||||
8501.10.59 |
8501.10.59 |
|
|
|
||||
8501.10.99 |
8501.10.99 |
|
|
|
||||
8501.20.19 |
8501.20.19 |
|
|
|
||||
8501.20.29 |
8501.20.29 |
|
|
|
||||
8501.31.40 |
8501.31.40 |
|
|
|
||||
8501.32.22 |
8501.32.12 |
|
|
|
||||
8501.32.32 |
8501.32.92 |
|
|
|
||||
8501.33.00 |
8501.33.00 |
|
|
|
||||
8501.34.00 |
8501.34.00 |
|
|
|
||||
8501.40.19 |
8501.40.19 |
|
|
|
||||
8501.40.29 |
8501.40.29 |
|
|
|
||||
8501.51.19 |
8501.51.19 |
|
|
|
||||
8501.52.19 |
8501.52.19 |
|
|
|
||||
8501.52.29 |
8501.52.29 |
|
|
|
||||
8501.52.39 |
8501.52.39 |
|
|
|
||||
8501.53.00 |
8501.53.00 |
|
|
|
||||
10 |
Electric generators |
8502.11.00 |
Explosion-proof electric generators |
8502.11.00 |
|
|
|
|
8502.12.10 |
8502.12.10 |
|
|
|
||||
8502.12.20 |
8502.12.20 |
|
|
|
||||
8502.13.20 |
8502.13.10 |
|
|
|
||||
8502.13.90 |
8502.13.90 |
|
|
|
||||
8502.20.10 |
8502.20.10 |
|
|
|
||||
8502.20.20 |
8502.20.20 |
|
|
|
||||
8502.20.30 |
8502.20.30 |
|
|
|
||||
8502.20.42 |
8502.20.41 |
|
|
|
||||
8502.20.49 |
8502.20.49 |
|
|
|
||||
8502.39.10 |
8502.39.10 |
|
|
|
||||
8502.39.20 |
8502.39.20 |
|
|
|
||||
8502.39.32 |
8502.39.31 |
|
|
|
||||
8502.39.39 |
8502.39.39 |
|
|
|
||||
11 |
Explosion-proof transformers |
8504.33.11 |
Explosion-proof transformers |
9817.30.10 |
|
|
|
|
8504.34.11 |
|
|
|
|||||
8504.34.14 |
|
|
|
|||||
8504.34.22 |
|
|
|
|||||
8504.34.25 |
|
|
|
|||||
8504.33.19 |
9817.30.90 |
|
|
|
||||
8504.34.12 |
|
|
|
|||||
8504.34.13 |
|
|
|
|||||
8504.34.15 |
|
|
|
|||||
8504.34.16 |
|
|
|
|||||
8504.34.23 |
|
|
|
|||||
8504.34.24 |
|
|
|
|||||
8504.34.26 |
|
|
|
|||||
8504.34.29 |
|
|
|
|||||
12 |
Static converters |
8504.40.90 |
Explosion-proof frequency converters |
8504.40.90 |
|
|
|
|
13 |
Communication equipment |
|
|
|
||||
13.1 |
Telephone sets, including telephones for cellular networks or for other wireless networks |
8517.11.00 |
Explosion-proof communication equipment (telephones, walkie-talkies, electric horns, electric belts) |
8517.11.00 |
|
|
|
|
8517.12.00 |
8517.12.00 |
|
|
|
||||
8517.18.00 |
8517.18.00 |
|
|
|
||||
13.2 |
Base stations |
8517.61.00 |
8517.61.00 |
|
|
|
||
13.3 |
Wireless LANs |
8517.62.51 |
8517.62.51 |
|
|
|
||
13.4 |
Electric sound or visual signalling apparatus |
8531.10.20 |
8531.10.20 |
|
|
|
||
8531.10.30 |
8531.10.30 |
|
|
|
||||
8531.10.90 |
8531.10.90 |
|
|
|
||||
8531.80.10 |
8531.80.11 |
|
|
|
||||
8531.80.19 |
|
|
|
|||||
14 |
Electrical apparatus for switching or protecting electrical circuits |
|
|
|
||||
14.1 |
Automatic circuit breakers, for a voltage exceeding 1,000 V |
8535.21.10 |
Explosion-proof electrical distribution and switching equipment (Magnetic starter, soft starter, circuit breaker, automatic breaker, earth leakage relay) |
8535.21.10 |
|
|
|
|
8535.21.20 |
|
|
|
|||||
8535.21.90 |
8535.21.90 |
|
|
|
||||
8535.29.10 |
8535.29.00 |
|
|
|
||||
8535.29.90 |
|
|
|
|||||
14.2 |
Isolating switches and make-and-break switches, for a voltage of 66 kV or more |
8535.30.20 |
8535.30.20 |
|
|
|
|
|
14.3 |
Automatic circuit breakers, for a voltage not exceeding 1,000 V |
8536.20.11 |
8536.20.11 |
|
|
|
|
|
8536.20.12 |
8536.20.12 |
|
|
|
||||
8536.20.19 |
8536.20.19 |
|
|
|
||||
14.4 |
Other apparatus for protecting electrical circuits, for a voltage not exceeding 1,000 V |
8536.30.90 |
8536.30.90 |
|
|
|
|
|
14.5 |
Relays for a voltage not exceeding 60 V |
8536.41.10 |
8536.41.10 |
|
|
|
|
|
8536.41.20 |
8536.41.20 |
|
|
|
||||
8536.41.30 |
8536.41.30 |
|
|
|
||||
8536.41.40 |
8536.41.40 |
|
|
|
||||
8536.41.90 |
8536.41.90 |
|
|
|
||||
14.6 |
Other relays |
8536.49.10 |
8536.49.10 |
|
|
|
|
|
8536.49.90 |
8536.49.90 |
|
|
|
||||
15 |
Explosion-proof control apparatus |
|
|
|
||||
15.1 |
Other apparatus for switching electrical circuits |
8536.50.99 |
Explosion-proof control apparatus (control panels, push button boxes) |
8536.50.99 |
|
|
|
|
15.2 |
Control panels for a voltage not exceeding 1,000 V |
8537.10.11 |
8537.10.11 |
|
|
|
||
8537.10.19 |
8537.10.19 |
|
|
|
||||
8537.10.92 |
8537.10.92 |
|
|
|
|
|||
8537.10.99 |
8537.10.99 |
|
|
|
|
|||
8537.20.21 |
8537.20.21 |
|
|
|
|
|||
8537.20.29 |
8537.10.29 |
|
|
|
|
|||
16 |
Electrical machines and apparatus, having individual functions |
8543.70.90 |
Electrical Blasting Machine |
8543.70.90 |
|
|
|
|
17 |
Electric wires and cables |
8544.20.11 |
Explosion-proof cables |
8544.20.11 |
|
|
|
|
8544.20.19 |
8544.20.19 |
|
|
|
||||
8544.20.21 |
8544.20.21 |
|
|
|
||||
8544.20.29 |
8544.20.29 |
|
|
|
||||
8544.20.31 |
8544.20.31 |
|
|
|
||||
8544.20.39 |
8544.20.39 |
|
|
|
||||
8544.42.94 |
8544.42.91 |
|
|
|
||||
8544.42.95 |
|
|
|
|||||
8544.42.96 |
|
|
|
|||||
8544.42.97 |
8544.42.92 |
|
|
|
||||
8544.42.98 |
|
|
|
|||||
8544.42.99 |
8544.42.99 |
|
|
|
||||
8544.49.22 |
8544.49.22 |
|
|
|
||||
8544.49.23 |
8544.49.23 |
|
|
|
||||
8544.49.29 |
8544.49.29 |
|
|
|
||||
8544.49.41 |
8544.49.41 |
|
|
|
||||
8544.49.49 |
8544.49.49 |
|
|
|
||||
8544.60.11 |
8544.60.11 |
|
|
|
||||
8544.60.19 |
8544.60.19 |
|
|
|
||||
8544.60.21 |
8544.60.21 |
|
|
|
||||
8544.60.29 |
8544.60.29 |
|
|
|
||||
18 |
Chandeliers and other electric ceiling or wall lighting fittings |
9405.10.91 |
Explosion-proof lamps |
9405.10.30 |
|
|
|
|
9405.10.92 |
9405.10.40 |
|
|
|
||||
9405.10.99 |
9405.10.90 |
|
|
|
||||
9405.40.20 |
9405.40.20 |
|
|
|
||||
9405.40.40 |
9405.40.40 |
|
|
|
||||
9405.40.60 |
9405.40.60 |
|
|
|
||||
9405.40.99 |
9405.40.99 |
|
|
|
||||
9405.60.90 |
9405.60.90 |
|
|
|
A Quick Intro |
Search Trade Information
|
|
|
|
|
|
|
|
|
Feature Information
|
|
|
|
|
|
|
Information & Articles
|
|
|
|
|
|
|
Contact Us! If you cannot find what you require in this website please feel free to contact us. Click here to send us a message >>>
|