Name | Provisions on lot sizes and sampling for examination Portland cement clinker |
---|---|
Description | The weight of each lot must not exceed 3.000 tons under Clause 6.1, Article 6 of Vietnam standard TCVN 7024:2002. Samples shall be taken under Clause 5.1 (Points 5.1.1 and 5.1.2), Article 5 of Vietnam standard TCVN 7024:2002. |
Comments | Samples shall be taken at at least 10 different positions of a clinker lot. each position with around 20 kg, which shall be mixed together and divided by four to get around 80 kg for testing. Samples for testing shall be equally divided by two, one part for storage and the other for testing. |
Validity From | 23-02-2010 |
Validity To | 31-12-2017 |
Reference | |
Technical Code | |
Agency | Ministry of Construction |
Created Date | 2018-02-12 22:05:22 |
Updated Date | 2018-02-12 22:05:22 |
Status | Inactive |
Measure Type | Technical Measures |
Legal/Regulation | Circular 01/2010/TT-BXD on Quality management of commercial portland cement clinker |
Un Code | B82 - Testing requirement |